Tension load cells for hoppers weighing, strength of linkage levers, and weigh scales, suspended weighing with ropes and rods etc.
Tension load cell
Click to enlarge image
Material | Stainless steel |
Nominal load | 3000, 5000, 6500, 8500, 12000 kg |
Limit load | 150 % F.S. |
Breaking load | 500 % F.S. |
Supply voltage | Vcc 15 Max |
Output | 1 mV/V |
Output tollerance | 0,1 % F.S. |
Zero tollerance | 2 % F.S. |
Linearity | 0,03 % F.S. |
Hysteresis | 0,03 % F.S. |
Reapeatability | 0,03 % F.S. |
Input resistance | 350-360 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 Mohm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4 / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 67 |
Standard cable length | 5 m – 4 x 0,25 (shield not connected to the load cell body) |
Type | SHIELDED CABLE 4C R5 PUR 4X0,25 |
Length | 5 m (body lead cell not connected shield) |
Red | + IN |
Black | - IN |
Green | + OUT |
White | - OUT |
General precautions to be followed in the installation and assembly of load cells: